How to Choose a BLDC Motor: 9-Step Selection Guide for OEMs

How to Choose a BLDC Motor: A 9-Step Selection Guide for OEMs

Quick Answer

To choose a BLDC motor, treat torque, speed and duty cycle as one coupled decision, not three separate checks. Work from the load backwards: define the duty cycle as a torque-versus-time profile, compute peak and RMS torque at the shaft, set the speed range, then pick bus voltage, Kv winding, gearbox ratio and feedback to satisfy all four. Size continuous current against T_rms with a 15–30% margin, confirm the voltage covers back-EMF plus I·R at top speed, and verify the thermal and IP rating at your real ambient. Peak torque answers whether the motor can move the load once; continuous torque answers whether it will survive the shift.

What Motor Selection Actually Involves

Choosing a BLDC motor is not a matter of matching a wattage on a nameplate. It is the process of reconciling four things that pull against each other: the torque your load demands, the speed it demands it at, the energy your power source can supply, and the heat your enclosure can reject. Every selection is a compromise somewhere in that quadrilateral, and the skill is knowing which corner you are allowed to give up.

The Six Inputs You Need Before Comparing Datasheets

Six inputs determine the answer, and none of them come from a motor catalogue. Load torque at the shaft, in newton-metres, for every phase of the cycle. Speed range, in rpm or linear velocity, including any low-speed dwell. Duty cycle, expressed as torque and duration for each segment, including idle. Available supply: voltage window, peak current and energy capacity. Mechanical interface: shaft, flange, gearbox, and the space envelope. And environment: ambient temperature range, ingress protection, altitude and expected service life.

Missing any one of the six forces a guess, and guesses surface later as field failures. The most frequently skipped is the duty cycle, which is also the one that most often lets you buy a smaller motor — the arithmetic is in our dedicated walkthrough on BLDC motor torque calculation.

Why Motor Selection Is a System Decision

A motor never operates alone. The controller sets the current ceiling, the gearbox sets the torque-speed trade, the power source sets the voltage window, and the mechanical structure sets the thermal path. Each of those can silently reduce a motor’s published capability by 20–40%. Selecting the motor first and integrating second is the standard order, and it is also the standard cause of “the motor is undersized” complaints where the motor is in fact correctly sized and the installation is not.

The Torque–Speed–Duty Triangle

Most selection guides present torque, speed and duty cycle as three independent lines on a checklist. Pick a torque, pick a speed, pick a duty rating, and the motor follows. That framing is convenient, and it is also the reason so many first prototypes overheat or stall. The three variables are not independent — each one constrains the other two.

Duty Cycle Sets the Thermal Ceiling

Duty cycle determines how much average current the winding can dissipate as heat before reaching its insulation limit, and that average current determines continuous torque. IEC 60034-1 defines duty types S1 to S9, with S3 denoting intermittent periodic duty expressed as an ED factor — the ratio of load time to total cycle time over a ten-minute reference cycle [1]. A motor rated S3 40% can carry its rated load four minutes in every ten and then cool for six. The same frame can carry a higher torque at S3 15% than at S1 continuous, because the off-time removes heat. Peak torque only answers a start-up question; duty cycle answers a survival question.

Torque Is Produced by Current, and Current Makes Heat

Torque follows T = Kt × I [9]. More torque at a fixed frame size means more current, more copper loss (I²R) and more heat. This is why a short high-torque burst costs far less thermally than the same torque sustained, and why the heating-equivalent RMS torque — not the peak — is the number to compare against a continuous rating.

Speed Rises as Torque Falls, Within a Voltage Ceiling

At a fixed supply voltage, torque falls approximately linearly from stall to no-load speed, and speed is bounded by Kv and the bus voltage. Running at high speed increases iron losses; running slowly under high load reduces self-cooling. Change one corner of the triangle and the other two move — a faster duty cycle leaves less cooling time, lowering allowable continuous torque, which may force a larger frame or a higher-voltage winding to deliver the same power.

How Electrical Specs Become Motion

Four electrical constants govern everything a brushless motor does, and they are linked in pairs. Understanding the pairing is what turns a datasheet from a list of numbers into a prediction.

Voltage, Kv and Speed

Kv is the motor’s speed constant: no-load rpm per applied volt. It fixes the relationship between bus voltage and top speed, before any losses are considered. A 200 rpm/V motor on 24 V spins at roughly 4800 rpm unloaded; load it and the speed falls by the resistive drop I × R_LL. Practical design leaves 15–30% headroom, so the target operating speed should sit at 70–85% of no-load speed at the minimum bus voltage, not the nominal one.

Current, Kt and Torque

The torque constant Kt is the mirror image: newton-metres per amp. It is numerically the reciprocal of Kv scaled by 9.5493, so Kt = 9.5493 / Kv when Kv is in rpm/V [9]. Torque then follows T = Kt × I, which means current — not voltage — is the quantity that sets torque, and heat is what limits how long you can sustain it. Continuous torque is therefore a thermal rating, and RMS current over the duty cycle is the number that must stay beneath it.

BLDC vs Brushed vs AC vs Stepper

Before optimising within brushless technology, confirm that brushless is the right family. The table compares the four candidates on the criteria that usually decide it.

CriterionBLDCBrushed DCAC inductionStepper
Efficiency at rated point85–92%70–80%80–93% (larger frames)50–70%
Torque densityHighModerateModerateLow at speed
MaintenanceBearings onlyBrush replacementBearings onlyBearings only
Low-speed smoothnessGood with FOCExcellentPoor without encoderPoor without microstepping
Controller cost and complexityModerate to highVery lowLow (VFD) or high (VSD)Low
Service life10,000–30,000 h1,000–5,000 h20,000 h+10,000 h+
Best fitBattery and variable-speed dutyCost-critical intermittent dutyFixed-speed mains dutyOpen-loop positioning

Where BLDC Loses

Brushless is not universally superior. Where a design runs at fixed speed from mains power, an AC induction motor with a VFD is often cheaper per kilowatt and needs no electronic commutation. Where positioning is open-loop and low-speed, a stepper avoids the feedback device entirely. And where the duty is intermittent and the unit cost target is brutal, a brushed motor still wins on bill of materials. The honest answer is that BLDC wins when efficiency, service life, torque density and controllability all matter at once — exactly the profile of battery-powered mobile equipment and precision fluid handling. The pump-specific version of this trade-off is covered in BLDC vs brushed DC motors for micro pumps.

The Ten Datasheet Numbers That Decide It

Suppliers publish a lot; ten numbers actually decide a selection. If a datasheet is missing more than two of these, treat the part as unselectable and ask for the data rather than estimating.

NumberWhat it tells youWhat goes wrong without it
Kv (rpm/V)Speed per volt, sets the winding choiceCannot predict top speed from the bus
Kt (N·m/A)Torque per amp, sets current demandCannot size the driver or the battery
R_LL (Ω)Copper loss and speed droopEfficiency and thermal estimates are guesswork
No-load current (A)Friction and iron lossesLow-load efficiency is overstated
Continuous torque (N·m)Thermal capability, the real ratingOverheating in service
Peak torque (N·m)Short-term overload ceilingStalls on acceleration or breakaway
Rotor inertia (kg·m²)Inertia matching and responsivenessSluggish or unstable servo loops
Thermal resistance (K/W)Temperature rise per watt of lossDerating is guesswork
Insulation classWinding temperature limitInsulation failure at high ambient
Efficiency mapEfficiency across the whole envelopeBattery runtime predictions are wrong

Continuous Torque, Peak Torque and RMS Torque

Three torque numbers on datasheets are routinely confused. Peak (stall) torque is the maximum at zero speed under a current limit, held only for seconds before the winding overheats — it sets whether the motor can break the load free. Continuous torque is what the motor can dissipate indefinitely at a stated duty and ambient, bounded by the insulation class, typically class B (130 °C) or F (155 °C) [1] — it sets whether the motor survives. RMS torque is the heating-equivalent torque of a repeating cycle: T_rms = sqrt( Σ(T_i² × t_i) / Σ(t_i) ) [9]. Compare T_rms against the continuous rating, and check the peak separately against the short-time rating.

Interpreting Efficiency Maps

A single peak efficiency figure is close to meaningless, because motors spend most of their life away from the peak point. A proper efficiency map plots contours across the torque-speed plane, and the shape matters more than the maximum: a motor that holds above 80% across a broad plateau will beat a motor with a higher peak and a narrow island, almost every time, on a real duty cycle. Where battery runtime is the binding constraint, the map is the document to ask for — the method is worked through in AGV motor efficiency and battery runtime.

Matching Motor Type to Application

Different application families penalise different mistakes, so the weighting of the nine steps shifts by sector. The table summarises where to spend the effort.

ApplicationDominant constraintPriority specCommon failure
AGV and mobile robot drivesBattery energy and duty cycleEfficiency map, T_rms, gearbox ratioSizing to peak instead of RMS
Micro gear pumps and dosingLow-speed torque and fluid behaviourContinuous torque, viscosity marginMaterial incompatibility with the fluid
Barrier gates and turnstilesDuty cycles with long holding torqueThermal path, holding currentWinding overheat during dwell
Stairlifts and platform liftsSafety, self-locking, audible noiseGearbox self-locking, dB(A) at distanceNoise complaints and brake drift
Robotic lawn mowersIP rating and grass-ingress coolingIP65, sealed bearings, thermal pathOverheating in a sealed enclosure
Conveyors and packagingContinuous duty, uptimeService life, bearing rating L10hBearing wear from side loading

Battery-Powered Mobile Platforms

On battery platforms everything traces back to energy. The pack has a fixed watt-hour budget, so efficiency maps directly to runtime, and the voltage window — from full charge down to the minimum usable state of charge — sets both the top speed and the current required to reach it. Cable and connector losses matter more at 24 V than at 48 V, which is why platform voltage is usually the first architectural decision and the hardest to change later. Our guide to sizing a BLDC motor for battery equipment covers the voltage-window arithmetic, and the platform-level comparison is in battery voltage selection for AGV motors.

Fluid Handling and Pumps

Pump duty looks simple — constant torque at a set speed — and is deceptive, because the load depends on differential pressure and on viscosity, which itself varies with temperature and with batch. A motor sized against water at 20 °C can be badly undersized against a cold, viscous product on a winter start-up. The rule we apply: size against the worst-case viscosity the process will actually see, and validate material compatibility for the actual fluid rather than for a surrogate.

The torque side of that calculation is derived in how much torque a gear pump needs. This article keeps the method application-agnostic; the full pump-specific treatment, including Kv winding selection and hydraulic load maths, is in how to choose a BLDC motor for a micro pump and the custom BLDC programme for micro pumps.

The Nine-Step Selection Procedure

The sequence below runs once through from mechanical requirement to validated prototype. Each step produces an artefact you can check, and skipping a step does not save time — it moves the cost from engineering to warranty.

StepActionArtefactGate
1Define load and duty cycleTorque-time profileEvery segment captured, including dwell
2Set speed and torque envelopeOperating envelope plotPeak and continuous both stated
3Choose bus voltageVoltage windowHeadroom at minimum state of charge
4Pick Kv / windingTarget KvTop speed at 70–85% of no-load
5Size torque and currentT_rms, I_peak, I_rmsT_rms 15–30% below continuous rating
6Select gearbox ratioRatio and efficiencyReflected inertia within ~10× rotor inertia
7Choose feedback and controlHall, encoder or sensorless; FOC or six-stepStart-up torque and ripple acceptable
8Verify thermal and environmentWinding temperature at worst caseMargin to insulation class at max ambient
9Prototype and validateMeasured duty cycleMeasured within 10% of calculation

Steps 1–4: Define Boundaries

These four steps are cheap and are where most value is created, because a poorly bounded problem cannot be rescued by a good motor. Capture the duty cycle as segments, extract peak and continuous envelopes, fix the voltage from the platform architecture, then derive Kv from the top-speed requirement at minimum bus voltage. Doing voltage before Kv matters: choosing Kv first frequently results in a winding that cannot reach the required speed on a partially discharged battery, and the fix is a rewinding exercise nobody budgeted for.

Steps 5–7: Size Torque, Gear and Control

Step 5 is where the money is decided. Convert the duty cycle into RMS torque and compare against the continuous rating with a 15–30% margin; then size peak current and confirm the driver can actually deliver it. The vehicle-flavoured version of the same arithmetic, with worked force coefficients, is in the AGV motor torque calculation guide; speed selection interacts with it at every step, covered in the AGV motor speed and RPM selection guide.

Step 6 trades ratio against inertia: reflected load inertia falls with i² while output torque rises only with i, so a modest ratio increase often allows a smaller motor. The comparison between geared and direct configurations is examined in gear motor vs direct drive for AGVs. Step 7 then fixes commutation quality — sensorless is adequate where start-up torque is low, Hall or encoder feedback is required where it is not, and the sensor trade-off is set out in Hall sensor vs sensorless BLDC motors.

Steps 8–9: Verify and Validate

Step 8 turns a mechanical selection into an environmental one: compute winding temperature at maximum ambient, in the real enclosure, with the real duty cycle, and check the margin to the insulation class. Thermal resistance from a datasheet assumes a standard fixture, so measure when the design is marginal. Step 9 closes the loop — instrument a prototype, record actual torque and speed across a full cycle, and reconcile against the calculation. A gap larger than about 10% usually means an input was wrong rather than the motor, and finding that out in prototype is far cheaper than finding it in the field. Programmes moving to volume should read the OEM AGV motor manufacturing guide before freezing the specification.

Worked Example: One Motor, Two Duty Profiles

The same torque and speed can need different frames once duty cycle enters. Consider a 24 V system that must deliver 0.30 N·m at 3000 rpm. Shaft power is P ≈ 0.30 × 3000 / 9.5493 ≈ 94 W. For a 20% no-load headroom, target n₀ ≈ 3600 rpm, so Kv ≈ 3600 / 24 = 150 rpm/V and Kt ≈ 9.5493 / 150 ≈ 0.0637 N·m/A. Delivering 0.30 N·m needs roughly I ≈ 0.30 / 0.0637 ≈ 4.7 A, and copper loss scales with that current squared.

Profile A — S1 continuous. The motor must dissipate I²R indefinitely. If the frame’s continuous rating at 24 V is 0.25 N·m, this 0.30 N·m load is over the thermal limit even though peak torque is available. Options: a larger frame, a higher-voltage and lower-Kv winding to cut current, or forced cooling.

Profile B — S3 25%. Running 2.5 minutes in a ten-minute cycle at the same torque, RMS torque is sqrt(0.30² × 0.25) = 0.15 N·m. Thermally the load is modest; the same frame that fails at S1 is comfortable at S3 25%, though peak torque still has to cover start-up current.

The lesson is that duty cycle, not peak torque, usually sets the frame. The same reasoning is applied to real platforms in the robotic mower motor comparison and the 24 V stairlift drive.

The Coupled Sizing Equations

These relations are the arithmetic behind the nine steps and are consistent with standard motor-test and duty-classification practice [1][4][5].

QuantityRelationUse
Torque from currentT = Kt × ISize drive current for a required torque
Torque constant from KvKt = 60 / (2π·Kv) ≈ 9.5493/KvConvert between speed and torque constants
Mechanical powerP(W) ≈ T(N·m) × n(rpm) / 9.5493Convert torque and speed to shaft power
Electrical powerP_in = V × I; η = P_out / P_inCheck supply and efficiency
Loaded speedn ≈ (V − I·R) × KvVerify speed under load, not at no load
Copper lossP_cu = I²RDominant heat source at high torque
RMS torqueT_rms = sqrt(Σ(T_i²·t_i)/Σ(t_i))Thermal-equivalent load for a duty cycle
ReductionT_out = T_motor × i × η_g; n_out = n_motor / iMatch motor to load through gearing

Together they form a closed loop: the load sets torque and speed; torque and speed set power; power and voltage set current through Kt; current sets heat; heat and duty set the allowable continuous torque; and that limit feeds back to the frame and Kv choice.

Eight Selection Mistakes

  • Selecting on power rating alone. A 200 W motor at 3000 rpm and one at 600 rpm are entirely different machines. Wattage without a speed is not a specification.
  • Sizing to peak torque. Heating tracks torque squared, so RMS is what sets the frame size. Peak-only sizing typically overspecifies by one frame.
  • Ignoring the voltage window. Battery platforms sag; design to the minimum bus voltage, not the nominal one, or the motor will miss top speed.
  • Choosing Kv for convenience. Too high a Kv means excess current and heat; too low means the speed target is unreachable. Derive it, do not inherit it.
  • Forgetting the controller. The driver’s current limit, not the motor’s, sets delivered torque. Specify them as a pair.
  • Treating continuous torque as installation-independent. The rating assumes a thermal path. Sealed plastic enclosures can remove a third of it.
  • Overlooking holding torque during dwell. A gate arm or a vertical axis holding against gravity still draws current and still heats the winding.
  • Assuming a surrogate fluid represents the real one. Viscosity and chemistry change both the load and the material requirements; validate compatibility and viscosity for the actual fluid.

Troubleshooting: Symptom to Spec Cause

Symptom in the fieldSpecification causeFix
Motor runs hot at rated loadContinuous rating assumed a better thermal path; T_rms underestimatedImprove mounting conduction or ventilation; re-derive T_rms from measured data
Cannot reach target speedKv too low, or bus voltage below the requirement at that currentRaise bus voltage or select a higher-Kv winding
Poor low-speed smoothnessSix-step commutation ripple, or sensorless operation below its reliable speedMove to FOC; add Hall or encoder feedback
Excessive audible noiseTorque ripple exciting a mechanical resonance, or PWM frequency in the audible bandRaise PWM above 16 kHz, use FOC, add mechanical damping
Driver trips on overcurrentPeak torque demand exceeds driver limit; acceleration ramp too aggressiveSoften the ramp, raise the limit if the motor allows, or raise the gear ratio
Battery runtime below predictionEfficiency at the operating point far below the datasheet peakRe-select using the efficiency map over the duty cycle, not the peak figure
Position drift in closed loopReflected inertia ratio too high, or gearbox backlash unaccounted forIncrease reduction, specify low-backlash gearing, retune the loop

Environmental and Compliance Factors

Environment converts an electrically correct selection into a field failure more often than any other cause, and it is the easiest category to specify correctly at the outset.

FactorTypical indoorOutdoor or washdownNote
Ingress protectionIP54IP65–IP67Sealing raises cost and worsens cooling
Ambient range0 to 40 °C-20 to 50 °CCold raises grease viscosity and breakaway torque
Insulation classClass F (155 °C)Class F or HClass B leaves little margin at 40 °C ambient
AltitudeUp to 1000 mDerate above 1000 mThinner air reduces convective cooling
Humidity and condensation<85% non-condensingSealed with drain or heaterCondensation corrodes windings and bearings

Ingress Protection and Ambient Range

IP rating and thermal capability pull in opposite directions: better sealing keeps contamination out and keeps heat in. A fully sealed IP67 housing can raise winding temperature by 20–30% relative to a ventilated IP54 design at identical load, which is why high-IP machines are frequently a frame size larger. Specify both limits together, and if the design is sealed, treat the motor frame and mounting flange as the primary heat path rather than the air. Lift and access equipment adds a further constraint — self-locking behaviour and audible noise — covered in our stairlift motor guide on 24 V BLDC motors for stairlifts.

Standards and Documentation

For export into North America and Europe, three documentation sets are usually requested: a CE declaration with the applicable machinery and EMC directives, UL or ETL recognition where the end product is listed, and efficiency evidence against IEC 60034-30-1 for machines in scope. Rotating machine ratings, performance and duty types are defined by IEC 60034-1 [1], and NEMA MG 1 [3] provides the North American counterpart for torque and thermal definitions. Ask for these at quotation stage rather than at first article — retrofitting compliance documentation is slower and more expensive than designing to it. Where a servo-grade alternative is being considered, the comparison in BLDC vs servo motors for AGVs sets out where each is justified.

Why Choose GreenSky?

GreenSky supplies BLDC and PMSM drive motors to pump and mobile-robot OEMs, and we publish the ten datasheet numbers above as standard rather than on request. That is a deliberate choice: a selection you cannot verify is a selection you cannot defend internally.

  • Full electrical disclosure — Kv, Kt, R_LL, no-load current, rotor inertia, thermal resistance and efficiency map on every datasheet, measured to IEC 60034 practice.
  • System-level sizing — motor, gearbox and controller specified as a matched set, so current limits, reflected inertia and torque ripple are resolved before sampling. See best motor types for AGVs and mobile robots for how we frame that decision.
  • Duty-cycle review in writing — send the torque-time profile and we return T_rms, peak and RMS current, voltage headroom and winding temperature, with the assumptions stated.
  • Environmental options — IP54 through IP67, Class F or H insulation, and low-temperature grease and sealing packages for outdoor and cold-chain equipment.
  • Prototype to volume continuity — the same winding and mechanical interface from sample through production, so step 9 validation stays valid at volume.

Send us six inputs. Load torque, speed range, duty cycle, supply window, mechanical interface and environment — and we will return a recommended motor, gearbox and controller set with the margins shown. Contact our engineering team →

Related resources

Choosing a BLDC motor for a micro pump · Barrier gate motor sizing and duty cycle · Selecting a 500 W BLDC motor · Motor application case studies

References

  1. International Electrotechnical Commission. (2026). IEC 60034-1:2026, Ed. 15.0 — Rotating electrical machines, Part 1: Rating and performance (duty types S1–S9). https://iec.ch/dyn/www/f?p=103:22:0::::FSP_ORG_ID:1221
  2. International Electrotechnical Commission. (2024). IEC 60034-30-1 — Efficiency classes for line-operated motors. https://iec.ch/dyn/www/f?p=103:22:0::::FSP_ORG_ID:1221
  3. NEMA. (2024). NEMA MG 1 — Motors and Generators. https://www.nema.org/standards/view/mg-1-motors-and-generators
  4. IEEE Standards Association. IEEE Std 112 — Standard Test Procedure for Polyphase Machines. https://standards.ieee.org/tag/power-and-energy/page/73/
  5. U.S. Department of Energy. 10 CFR Part 431, Subpart B — Energy Efficiency Program for Electric Motors. https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-431
  6. International Energy Agency. Energy efficiency — motor systems. https://www.iea.org/energy-system/industry/motors
  7. SKF. Rolling bearings — selection and service life. https://www.skf.com/us/products/rolling-bearings
  8. Siemens. SIMOTICS motors — selection and engineering tools. https://www.siemens.com/en-us/products/simotics/
  9. FAULHABER. Brushless DC motors — technology and selection criteria. https://www.faulhaber.com/en/products/brushless-dc-motors/
  10. maxon. Brushless DC motors and drive systems — design resources. https://www.maxongroup.com/en

FAQ

Q: What are the first things to check when choosing a BLDC motor? Start with the load, not the motor: peak and continuous torque at the shaft, the speed range, the duty cycle as a torque-versus-time profile, and the available bus voltage. Those four inputs determine the frame size, the winding and the gearbox ratio. Only after they are fixed should you compare datasheets, because every electrical constant on a datasheet is meaningless without a load to test it against.

Q: Is peak torque or continuous torque more important? Continuous torque decides whether the motor survives; peak torque decides whether it can start the load. Anything that repeats must be sized on RMS and continuous torque at the stated duty. Peak torque only confirms the motor can break the load free and accelerate it within the drive current limit. A short burst well above the continuous rating is thermally cheap, while a load just above it held for most of a cycle will overheat the winding.

Q: How do I choose between 24 V, 36 V and 48 V BLDC motors? Higher voltage reduces current for the same power, which cuts copper loss and allows thinner cable, but it raises insulation and safety requirements. Below about 300 W, 24 V is usually sufficient and cheapest. Between 300 W and 1 kW, 36 V or 48 V typically wins on efficiency. If torque demand is high, raising the bus voltage and lowering Kv keeps the same speed and torque while cutting current and reducing copper loss by roughly four times, which is often the cheapest way to buy thermal headroom.

Q: What Kv should I pick for a BLDC motor? Choose Kv so the required top speed sits at roughly 70 to 85 percent of the no-load speed at your minimum bus voltage. Kv is no-load rpm per volt, so a 24 V pack with a 20 V minimum and a 3000 rpm target needs about 150 rpm per volt before allowing for resistive drop. Kt is the reciprocal constant, about 9.5493 divided by Kv, so a higher Kv gives less torque per amp and demands more current for the same torque. Derive Kv from the load; do not inherit it.

Q: Do I need a gearbox, or should I use a direct-drive BLDC motor? Use a gearbox when the load needs high torque at low speed: reflected load inertia falls with the square of the ratio while torque capability rises only linearly, so a modest ratio increase often allows a smaller motor. Direct drive wins when backlash, noise, maintenance and efficiency matter more than size, as in hub motors, fans and some pump drives. A practical test is whether the reflected load inertia is within about ten times the rotor inertia.

Q: What duty cycle and environmental ratings should I specify? Match the duty type to the thermal pattern: S1 for continuous running, S3 with an ED of 15, 25, 40 or 60 percent for a repeating load and rest cycle, and S4 or S5 when starts and electrical braking add significant loss. Rate at the worst-case duty and ambient. Specify IP54 for most indoor equipment and IP65 or higher for washdown or outdoor use, Class F insulation with a 155 degrees C winding limit as the industrial default, and derate above 1000 m altitude because thinner air reduces convective cooling.