Tìm kiếm

Mặt bích động cơ là gì

Bộ bánh răng giun B14 mặt bích

Mặt bích động cơ là gì? The Complete Engineering Guide to B5, B14 & NEMA C-Face Mounts

Trả lời nhanh

A motor flange is the machined, disc-shaped mounting face on the drive end of an electric motor that lets it bolt directly and coaxially to a pump, hộp số, or other driven machine — with no separate base or coupling alignment. The flange has a precision spigot (also called a pilot or register) that centers the motor, and a ring of mounting holes on a defined pitch circle diameter (PCD). International standard IEC 60034-7 defines flange mounts with IM codes such as IM B5 (large flange, clearance/through holes = FF type) Và IM B14 (small flange, tapped/threaded holes = FT type); dimensions come from IEC 60072. In North America the equivalent concepts are the NEMA C-face (threaded holes) Và D-flange (through holes) defined in KHÔNG CÓ MG 1. Choosing the wrong flange type is the single most common motor ordering error.

Bộ bánh răng giun có mặt bích 63B5-Mặt bích động cơ là gì

Mặt bích động cơ là gì? (Sự định nghĩa)

MỘT motor flange is a flat, machined ring or plate on the drive end (DE) of a motor that replaces — or supplements — the traditional mounting feet. Instead of resting on a base, a flange-mounted motor is fastened face-to-face onto the driven equipment. Because the flange and its spigot are machined in the same operation as the bearing housing, the motor shaft ends up automatically concentric with the mating bore, so no field alignment is needed.

Every motor flange is built from three functional features, and understanding them is the key to specifying the correct part:

1. The spigot (pilot / register / rabbet)

Các spigot is a short cylindrical shoulder machined concentric to the shaft. It slots into a matching recess in the gearbox or pump housing and does the actual centering work — the bolts only clamp. IEC calls it the spigot or pilot; NEMA calls it the rabbet or register (kích thước AK). Its concentricity to the shaft is tightly toleranced under IEC 60072-1.

2. The mounting holes and pitch circle diameter (PCD)

The bolt holes sit on a pitch circle diameter (PCD), also called the bolt circle diameter (BCD) or NEMA AJ. The holes are either clearance (through) holes — you pass a bolt through the flange into a tapped machine housing (IEC FF / KHÔNG CÓ D-flange) — or tapped (threaded) holes — you screw a bolt from the machine side into the motor face (IEC FT / KHÔNG CÓ C-face).

3. The flange outer diameter and thickness

These set the envelope and the load path. On a large FF/B5 flange the outer diameter is bigger than the motor body; on a small FT/B14 flange it is usually equal to or smaller than the body. The flange must carry the full cantilevered weight and torque reaction of the motor, so its thickness is a structural, not cosmetic, kích thước.

Bộ bánh răng giun B5 mặt bích

How a Flange Mount Works: Từng bước một

  1. The spigot enters the housing bore. The machined pilot diameter is a close (often h7/H8) slip fit into the mating recess of the gearbox, pump adapter, or bracket. This locates the motor radially and forces the shaft axis to coincide with the driven-shaft axis.
  2. The faces seat flat. The machined flange face contacts the machine face squarely, setting axial position and squareness (perpendicularity of the shaft to the mounting plane).
  3. The coupling engages. Because the shaft is now pre-aligned by the spigot, a rigid or short flexible coupling — or a direct splined/keyed input into a gearbox — can be joined without dial-indicator alignment.
  4. The bolts clamp. Bolts on the PCD are torqued to develop a clamp load that resists the motor’s weight and the reaction torque. Clamp force, not friction from a loose fit, keeps the joint rigid: F = T / (K·d), where T is bolt torque, d bolt diameter, and K the nut factor (~0.2 for dry steel).
  5. Load transfers through the flange. Weight and vibration flow from the motor, through the flange ring, into the machine structure — which is why flange concentricity and stiffness directly affect bearing life and vibration.

The result is a compact, self-aligning, floor-space-free drive. That is exactly why close-coupled pumps, speed reducers, and OEM machines overwhelmingly use flange motors instead of foot-mounted ones.

Motor Flange Types Compared (IEC 60034-7)

IEC 60034-7 assigns each mounting arrangement an TÔI (International Mounting) code. The four flange-related codes below cover almost every industrial flange motor. The most important — and most confused — distinction is B5 vs. B14: B5 has clearance holes (bolt passes through the flange), while B14 has tapped holes (bolt threads into the flange).

CodeIM numberFlange typeHole typeFlange vs. body ODTypical use
B5TÔI 3001 (IM B5)Large flange (FF)Clearance / throughLarger than bodymáy bơm, hộp số, bộ giảm tốc, agitators
B14TÔI 3601 (IM B14)Small face flange (FT)Tapped / threadedEqual or smallerSmall pumps, công cụ máy móc, compact drives
B35TÔI 2001 (IM B35)Chân + large flangeClearance (FF) + feetLarger than bodyHeavy reducers, mô-men xoắn cao, trang bị thêm
B34TÔI 2101 (IM B34)Chân + face flangeTapped (FT) + feetEqual or smallerBelt drive + face mount combo, OEM

Vertical variants (shaft down = V1, shaft up = V3/V18) use the same flanges but need thrust-rated bearings and, outdoors, a rain canopy. For a foot-mounted comparison, see our guide to AC vs. động cơ điện một chiều.

Hộp số Worm có mặt bích đầu ra

IEC Flange vs. NEMA Flange (Global Sourcing)

North American equipment uses NEMA MG 1 terminology instead of IM codes. Functionally they map cleanly, but the dimensions and frame numbers differ, so an IEC B5 motor will không bolt to a NEMA D-flange housing without an adapter.

Tính năngIEC (60034-7 / 60072)KHÔNG CÓ (MG 1)
Tapped-hole flangeFT flange = B14C-face (ví dụ. 56C, 143TC)
Through-hole flangeFF flange = B5D-flange (ví dụ. 56Đ., 254TD)
Centering featureSpigot / pilot / registerRabbet / register (dim AK)
Bolt circlePitch circle diameter (PCD)Bolt circle (dim AJ)
Flange ODFlange outer diameterKích thước BD
Size unitMillimetresInches
Dimensional standardIEC 60072-1KHÔNG CÓ MG 1 / IEC 60072

FF and FT Flange Designations Explained

Under IEC 60072-1, a flange is named by its type letters plus the pitch circle diameter in millimetres. Vì thế FF265 means a through-hole (FF) flange with a 265 mm PCD; FT115 means a tapped (FT) flange with a 115 mm PCD. The table pairs common IEC frame sizes with their standard flange.

IEC frameStd. B5 flange (FF)PCD (mm)Spigot Ø N (mm)Std. B14 flange (FT)
63FF11511595FT75
71FF130130110FT85
80FF165165130FT100
90FF165165130FT115
100 / 112FF215215180FT130
132FF265265230FT165
160FF300300250FT215
180FF300300250
200FF350350300

Spigot diameter “N” is the pilot register the housing bore must match. Values follow IEC 60072-1; always confirm against the specific manufacturer datasheet before machining a mating part.

Motor Flange Engineering Data: Tolerances, Loads & Công thức

A flange looks simple, but its performance is governed by tight geometric tolerances and a real mechanical load path. Getting these numbers right is what separates a vibration-free drive from premature bearing failure.

Concentricity and run-out tolerances (IEC 60072-1)

IEC 60072-1 defines two tolerance grades for the spigot and face: Normal (N)Reduced (r) for precision applications. The spigot must be concentric to the shaft, and the mounting face perpendicular to it, within these limits (total indicator reading, TIR):

Spigot Ø N (mm)Concentricity — Normal (mm)Concentricity — Reduced (mm)Face perpendicularity — Normal (mm)
≤ 2500.100.050.10
> 250 ĐẾN 5000.1250.0630.125
> 500 ĐẾN 8000.160.080.16

Exceed these and the shaft runs eccentric to the driven bore, injecting a once-per-revolution radial force that shortens bearing L10 life and raises vibration.

Key formulas for flange-mounted drives

  • Bolt clamp load: F = T / (K · d) — clamp force F from torque T, bolt diameter d, nut factor K (≈0.20 dry, ≈0.15 lubricated). Under-torqued flange bolts let the joint fret and loosen under vibration.
  • Reaction torque on the flange: T = P × 9550 / N (N·m), with power P in kW and speed n in rpm. This is the torque the flange bolt pattern must react at start-up and stall.
  • Bolt shear from reaction torque: Fbolt = 2T / (Nb · PCD) — tangential load per bolt, with nb bolts on the pitch circle diameter. Larger PCD = lower per-bolt load.
  • Cantilever bending on the flange: M = W · Lcg — motor weight W acting at its center-of-gravity distance Lcg from the flange face; the reason large motors prefer B35 (foot + mặt bích) over B5 alone.
  • Bearing L10 life: L10h = (10⁶ / 60N) · (C/P)³ for ball bearings — misalignment from a poor flange fit raises the equivalent load P and cuts life cubically (nhìn thấy SKF bearing calculator).

Worked example

MỘT 7.5 kW, 1,450 rpm B5 motor on an FF265 flange (PCD 265 mm, 4 bolts): reaction torque T = 7.5 × 9550 / 1450 ≈ 49 N·m. Tangential load per bolt Fbolt = 2 × 49 / (4 × 0.265) ≈ 92 N — small, so the bolts are sized by clamp/vibration, not shear. This confirms why correct preload torque matters more than bolt count on most flange motors.

Materials and typical thermal limits

Flanges are cast iron (heavy-duty rigidity), nhôm (light OEM frames), or fabricated/stainless steel (washdown). Insulation class governs the surface heat the flange transmits into the driven machine: Lớp b 130 ° C., Lớp F 155 ° C., Lớp H 180 ° C. mỗi IEC 60034-1 — relevant when a plastic pump adapter meets a hot motor flange.

Best Applications for Flange-Mounted Motors

Ứng dụngPreferred flangeTại sao
Close-coupled centrifugal pumpsB5 / D-flangeDirect axial coupling, self-aligning, no baseplate
Gearboxes & speed reducersB5 / B14Motor bolts straight to reducer input bell — see our hộp số guide
Compact machine tools & máy dệtB14 / C-faceSmall footprint, tapped-hole face fits limited space
Máy trộn & agitators (vertical)B5 V1Shaft-down flange mount with thrust bearing
Băng tải & heavy reducersB35 (foot + mặt bích)Flange aligns, feet carry weight & rung động
OEM pump/gear assembliesB14 / C-faceStandardised pilot for modular, interchangeable builds

How to Select the Right Motor Flange: Từng bước một

  1. Confirm the standard. IEC (metric, IM codes) or NEMA (inch, C/D-face)? This is set by your existing machine, not preference.
  2. Read the mating housing. Measure the recess bore (this must equal the motor spigot Ø N / AK) and the bolt circle (PCD / AJ). These two numbers define the flange.
  3. Identify the hole type. Do bolts pass through the flange into a tapped housing (B5 / D-flange, FF) or thread into the motor face (B14 / C-face, FT)? This is the #1 mistake — verify with a photo or thread gauge.
  4. Match the frame & trục. The flange PCD is tied to frame size; also confirm shaft diameter, chiều dài, and key so the coupling fits.
  5. Check load direction. Heavy motor, rung động, or overhung load? Step up to B35 (foot + mặt bích) rather than trusting the flange bolts alone.
  6. Specify tolerance grade. Precision spindles or high-speed pumps warrant the Reduced (r) concentricity grade, not Normal (N).
  7. Select material & enclosure. Cast iron for industrial rigidity, stainless for washdown, aluminium for light OEM; then pick IP/enclosure rating.

Common Engineering Mistakes with Motor Flanges

  • Confusing B5 and B14. They look similar but B5 has clearance holes and B14 has tapped holes. A B14 ordered as B5 will not bolt on. This is the most frequent flange ordering error.
  • Matching PCD but ignoring the spigot. Two flanges can share a bolt circle yet have different pilot diameters — the motor won’t center. Always match spigot Ø N (AK) PCD (AJ).
  • Mixing IEC and NEMA. An IEC B5 flange will not fit a NEMA D-flange housing; the metric/inch dimensions differ. Use an adapter plate or order to the correct standard.
  • Overloading a bare B5 flange. Using flange-only mounting for a heavy or overhung load overstresses the flange bolts and bends the mounting face. Move up to B35.
  • Under-torquing the bolts. Insufficient clamp load lets the joint fret, loosen, and shift under vibration. Torque to spec using F = T/(K·d).
  • Forcing a vertical mount. Turning a horizontal B5 motor shaft-down without a thrust-rated bearing (and rain canopy outdoors) leads to early bearing failure.
  • Paint or burrs on the spigot/face. Contamination breaks the flat face contact and concentric fit, re-introducing the misalignment the flange was meant to remove.

Motor Flange Troubleshooting Table

Vấn đềLikely causeGiải pháp
Motor won’t bolt to housingWrong flange type (B5 vs B14) or IEC/NEMA mismatchVerify hole type & tiêu chuẩn; use adapter or correct motor
Bolts line up but motor won’t seatSpigot Ø doesn’t match the housing recessMatch pilot register Ø N / AK, not just PCD
High vibration after mountingSpigot concentricity out of tolerance, or burrs/paint on faceClean & deburr faces; check TIR to IEC 60072-1 cấp
Recurring bearing failureShaft misalignment from poor flange fit; tải quá tảiRe-check spigot fit; add support or switch to B35
Flange bolts keep looseningUnder-torque / no clamp preload; rung độngTorque to spec, add thread-locker or lock washers
Flange face cracked or bentOverhung/heavy load on flange-only (B5) mountUpgrade to foot + mặt bích (B35); check load path
Water in motor (vertical mount)Shaft-up without seal / shaft-down without canopyAdd rain canopy or shaft seal; specify V-mount properly
Coupling still needs alignmentNon-precision (Normal) flange used on precision driveSpecify Reduced (r) tolerance grade flange

Câu hỏi thường gặp

What is a motor flange used for?

A motor flange lets a motor bolt directly and coaxially onto a pump, hộp số, or machine without a separate base or dial-indicator alignment. The machined spigot centers the shaft automatically, saving floor space and installation time.

What is the difference between a B5 and B14 flange?

A B5 flange is large, has clearance (through) holes, and its outer diameter is bigger than the motor body — the bolt passes through the flange into the machine. A B14 flange is smaller, has tapped (threaded) holes on the face, and the bolt threads into the motor. Confusing the two is the most common ordering error.

What is the spigot (register) on a motor flange?

The spigot — also called the pilot, register, or NEMA rabbet — is a precision machined shoulder concentric to the shaft. It fits into a matching bore in the driven equipment and does the actual centering; the bolts only clamp. Its diameter must match the housing exactly.

Are IEC and NEMA flanges interchangeable?

KHÔNG. IEC flanges (B5/B14, metric, IM codes) and NEMA flanges (D-flange/C-face, inch) use different dimensions and frame numbering. An IEC motor will not bolt to a NEMA housing without an adapter plate, even if the concepts are equivalent.

What does FF265 or FT115 mean?

Under IEC 60072-1 the number is the pitch circle diameter in millimetres. FF265 is a through-hole flange with a 265 mm PCD; FT115 is a tapped-hole flange with a 115 mm PCD. The letters give the hole type (FF = clearance, FT = tapped).

When should I use B35 instead of B5?

Use B35 (foot + mặt bích) when the motor is heavy, carries an overhung load, or is subject to strong vibration. The feet carry the weight and damp vibration while the flange still aligns the drive — reducing stress on the flange bolts and face.

Why Choose Greensky for Flange-Mounted Motors?

Từ 2011, năng lượng bầu trời xanh has engineered động cơ BLDC, động cơ DC chải, động cơ bước, Và hộp số with correctly machined flanges for OEM customers in over 50 Quốc gia. When the mounting interface has to be right the first time, our engineers spec the flange with you — spigot, PCD, tolerance grade, and standard.

  • Both standards: IEC B5/B14/B35 and NEMA C-face / D-flange, plus custom pilot diameters.
  • Precision machining: spigot concentricity and face perpendicularity held to IEC 60072-1 điểm.
  • Integrated drives: động cơ + gearbox supplied as a matched flange assembly — no adapter guesswork.
  • 100% thử nghiệm: every unit run-tested; run-out and vibration verified.
  • Tuân thủ tiêu chuẩn: được thiết kế theo tiêu chuẩn IEC 60034 / KHÔNG CÓ MG 1 luyện tập; iso, CE certified.
  • OEM/ODM support: full engineering help through United Motion Inc. in North America & Châu Âu.

Yêu cầu giải pháp động cơ tùy chỉnh →

Nhận báo giá miễn phí

Tài liệu tham khảo

  1. IEC 60034-7, Rotating electrical machines — Classification of types of construction, mounting arrangements and terminal box position (IM code). https://webstore.iec.ch/publication/2765
  2. IEC 60072-1, Dimensions and output series for rotating electrical machines — Frame numbers 56 ĐẾN 400 and flange numbers 55 ĐẾN 1080. https://webstore.iec.ch/publication/351
  3. IEC 60034-1, Máy điện quay - Đánh giá và tính năng. https://webstore.iec.ch/publication/60034-1
  4. KHÔNG CÓ MG 1, Động cơ và máy phát điện (C-face, D-flange, AJ/AK dimensions). https://www.nema.org/standards/view/motors-and-generators
  5. KHÔNG CÓ MG 1-2009 (toàn văn, Law.resource.org). https://law.resource.org/pub/us/cfr/ibr/005/nema.mg-1.2009.pdf
  6. ABB, Low voltage motors — Mounting arrangements and IM codes (technical guide). https://new.abb.com/motors-generators/iec-low-voltage-motors
  7. Siemens, SIMOTICS General Purpose Motors — Types of construction / gắn. https://www.siemens.com/global/en/products/drives/electric-motors.html
  8. SKF, Bearing rating life (L10) and mounting/alignment guidance. https://www.skf.com/group/support/engineering-tools/bearing-calculator
  9. IEEE Standard 112, Test Procedure for Polyphase Induction Motors and Generators. https://standards.ieee.org/ieee/112/4703/
  10. CHÚNG TA. Sở năng lượng, Motor Systems — Energy Conservation Program (10 Phần CFR 431). https://www.energy.gov/eere/motors

Bạn cũng có thể thích

Motors for Warehouse AGVs: Các loại, Specs & Selection by Vehicle Class | GreenSky

Động cơ AGV quá nóng: nguyên nhân, Giới hạn nhiệt và giải pháp kỹ thuật

Thoát lưới

Gửi yêu cầu của bạn ngày hôm nay

Hình ảnh của Kyle

Kyle

Kỹ sư bán hàng | Nhà cung cấp động cơ điện một cửa có kinh nghiệm tại Trung Quốc (Động cơ DC/Động cơ BLDC/Động cơ bước/Động cơ bánh răng)
Sức mạnh Greensky WeChat

Vui lòng để lại email công việc của bạn.

Hãy cho chúng tôi biết về nhu cầu của bạn