Monitoring in motor operation
After the động cơ không đồng bộ ba pha is put into operation, it should be monitored and maintained frequently to understand its working condition and find out the abnormal phenomenon in time to give reasonable treatment and eliminate the fault in the bud. In the process of operation monitoring, the on-site maintenance personnel can roughly judge the operation status of the motor by listening, watching, smelling and touching with working experience.

Ví dụ, when the sound issued during the operation of the motor is a regular crisp sound, commonly known asmachine music”, it means that the motor is running in light load or normal operation state; if a very dull sound is issued, it means that the motor is in heavy load operation state; if there is a burnt or pungent odor when the motor is running, it means that the temperature rise of the motor is too high. The motor should be stopped as soon as possible.

The monitoring work in motor operation mainly includes the following aspects.

(1) Monitor the change of power supply voltage. Normally, the fluctuation value of power supply voltage should not exceed ±10% of the rated voltage, and the difference between any two phase voltage should not exceed 5%. In order to monitor the power supply voltage, it is better to install a voltmeter and changeover switch on the động cơ power supply.

(2) Monitor the running current of the motor. Under normal condition, the running current of the motor should not exceed the rated current indicated on the nameplate. Đồng thời, you should also pay attention to whether the three-phase current is balanced. Normally, the difference between any two phases should not be more than 10% của dòng điện định mức. For motors with larger capacity, current meter should be installed to monitor; for motors with smaller capacity, clamp current meter should be used to measure at any time.

(3) Monitor the temperature of the motor. The temperature rise of the motor should not exceed the allowed temperature rise limit indicated on the nameplate. Check the temperature rise of motor can be measured by thermometer. The easiest way is to touch the motor shell with the back of hand, if the motor is hot, it means the motor is overheated, tại thời điểm này, you can sprinkle some drops of water on the shell, if the water vaporizes sharply and there issizzlingsound, it means the motor is obviously overheated.

 

CHIA SẺ BÀI NÀY

Bạn cũng có thể thích

Tiêu chuẩn kiểm tra động cơ điện: Tổng quan toàn cầu

Tiêu chuẩn kiểm tra động cơ điện: Tổng quan toàn cầu Thử nghiệm động cơ điện là một quá trình quan trọng nhằm đảm bảo chất lượng và hiệu suất của các bộ phận thiết yếu này trong[...]

UM và Tập đoàn Điện lực Ngọa Long thiết lập quan hệ đối tác chiến lược.

United Motion Inc. và Tập đoàn Điện lực Ngọa Long đã thiết lập quan hệ đối tác chiến lược. United Motion Inc., Mỹ. công ty con của Greensky, vui mừng thông báo một[...]
Thoát khỏi lưới điện

Gửi yêu cầu của bạn ngày hôm nay

bầu trời xanh.năng lượng

Sức mạnh Greensky WeChat

Hãy cho chúng tôi biết về nhu cầu của bạn