What Causes a DC Motor to Lose Torque?

Schnelle Antwort: A DC motor loses torque because the torque constant kT falls (permanent-magnet demagnetization from over-current or heat), das available armature current drops (low supply voltage, a current-limited drive, or a shorted winding), oder mechanical friction rises (worn bearings, a dragging gearbox, oder echte Überlastung). Torque is governed by the relation T = kT·ICHa, so any factor that reduces kT or Ia directly reduces shaft torque. In a documented 24 V PMDC example, simply raising the winding temperature from 25 °C to 125 °C cuts the torque constant about 20% and locked-rotor torque from ~2.9 Nm to ~1.65 Nm. The most common root causes are over-current demagnetization, Unterspannung, thermal drift, winding faults, Überlast, and brush/commutator wear.

What DoesLosing TorqueMean in a DC Motor?

Motor torque is the rotational force the shaft delivers to the load, expressed in newton-meters (Nm) or ounce-inches (oz-in). Bei einem Gleichstrommotor, torque is produced by the interaction of the magnetic field and the current flowing in the armature windings. The shaft torque at any instant is:

  • T = kT · Ia — torque equals the torque constant times the armature current.
  • For a permanent-magnet DC (PMDC) Motor-, kT is set by the magnet flux and the number of effective turns; it is a fixed property until the magnets weaken.
  • For a wound-field motor, kT also depends on the field current — a weak field directly lowers torque.

Losing torquetherefore means one of two things has changed: either kT has dropped (the machine makes less torque per amp) oder icha has dropped (less current is reaching or being used by the armature). Every cause in this article maps to one of those two variables. To understand the parts involved, start with our guide to what a DC motor is and how it is built.

Was bewirkt, dass ein Gleichstrommotor Drehmoment verliert
Was bewirkt, dass ein Gleichstrommotor Drehmoment verliert

The Two Variables That Decide Torque

VariableWhat changes itEffect on torque
kT (torque constant)Magnetstärke, effective turns, field currentFalls with demagnetization or shorted turns → less torque per amp
icha (armature current)Versorgungsspannung, Wicklungswiderstand, Belastung, drive limitFalls with low voltage, high R, Überlast, or current cap

Wie ein Gleichstrommotor Drehmoment erzeugt (and Where It Leaks)

A DC motor is a closed electromechanical loop. Follow the chain and you can see exactly where torque is lost:

  1. Supply applies voltage (vT) across the brushes or the drive terminals.
  2. Aktuell (icha) flows in the armature windings sitting in the magnetic field (B) from the permanent magnets or field coils.
  3. The Lorentz force (F = B·I·L) on each conductor produces a torque about the shaft.
  4. The rotor accelerates, and a back-EMF (Eb = kE·Oh) builds up, opposing the supply.
  5. Steady state is reached when Eb ≈ VT − Ia·Ra, fixing the current and therefore the torque T = kT·ICHa.

The governing equations make the leak points obvious:

  • Endsaldo: vT = Eb + icha·Ra
  • Gegen-EMF: Eb = kE·Oh (and in SI units, kE ≈ kT)
  • Geschwindigkeitsgleichung: ω = (vT/kE) - (Ra/kE·kT)·T

Trace the failure modes through these equations:

  • Low supply voltage → lower Ia available → lower torque and lower speed.
  • Demagnetized magnets → lower kT and kE → less torque per amp, higher speed at no load.
  • Hot winding → Ra rises and kT falls → less current and less torque at the same voltage.
  • Shorted armature turns → fewer effective turns → lower kT, higher current, mehr Hitze.
  • Lager verschlissen / dragging gearbox → load torque rises → Ia climbs until the drive or thermal protection limits it.

Brushed PMDC vs Brushless (BLDC): Where Torque Leaks

Both types use permanent magnets and obey T = kT·ICHa, but the failure map differs because commutation is mechanical in one and electronic in the other.

Cause of torque lossBrushed PMDCBrushless PMDC (BLDC)
Permanent-magnet demagnetizationYes — over-current / HitzeYes — same physics
Brush friction (no-load torque MR)Yes — wears brushes, raises MRKeiner (keine Bürsten)
Commutation timingMechanical off-neutral settingElectronic — wrong Hall angle (60°/120°)
Drive current limitSimple supply (rarely capped)PWM current cap — common cause ofweak” Drehmoment
Winding fault testWiderstand von Stange zu StangePhase-to-phase balance

For a deeper look at brush wear and sparking, Sehen Sie sich unseren Leitfaden an why brushed motors spark, and for electronic-commutation trade-offs read Nachteile des BLDC-Motors.

Root-Cause Comparison Table

The table below ranks the seven most common causes by how they attack the torque equation. Use it to triage a motor that feels weak.

#UrsacheAttacksTypical symptomReversibel?
1Over-current demagnetizationkTHigh no-load speed, niedriges Drehmoment, runs hot under loadNo — magnets damaged
2Low supply voltageichaSlow, weak, especially under loadYes — fix supply
3Thermal drift (Hitze)kT ↓, Ra Torque sags as the motor warms upPartial — allow cooling
4Winding fault (kurzgeschlossene Windungen)kT ↓, RaOverheats, high current, niedriges DrehmomentNo — rewind/replace
5Mechanical overloadicha capped → T cappedStalls, trips breaker, high currentYes — reduce load
6Bürste / commutator wearMR , schlechter KontaktFunkenbildung, uneven torque, slow startYes — service brushes
7Fahren / controller limiticha cappedWeak only under load, fine unloadedYes — raise current limit

Technische Daten: Drehmomentformeln & Ausgearbeitetes Beispiel

Quantifying torque loss turns guesswork into measurement. These are the relations used by manufacturer datasheets such as FAULHABER and maxon.

MengeFormelUse in diagnosis
DrehmomentT = kT·ICHaStrom legt Drehmoment fest; kT is the multiplier
Stall (locked-rotor) DrehmomentTLR = (vT/Ra)·kTMaximum torque at zero speed (FAULHABER MH)
Gegen-EMFEb = kE·OhSpin test confirms kE = kT (UND)
Ankerstromicha = (vT − Eb)/RaLow VT or high Ra → low Ia
Terminal resistance vs tempR(F) = R(ich)·[1 + αcond(θf − θi)]Copper αcond ≈ +0.004 K−1 (FAULHABER)
Torque constant vs tempk(F) = k(ich)·[1 + αmag(θf − θi)]Magnet αmag ≈ −0.002 K−1 (negative)

Ausgearbeitetes Beispiel: Heat Alone Cuts Torque ~20%

This is taken from a published PMDC thermal analysis (Haydon Kerk Pittman). EIN 24 V motor has Ra = 0.59 Ω and kT = 0.071 Nm/A at 25 ° C. Compare 25 °C to 125 ° C:

ParameterBei 25 ° CBei 125 ° CÄndern
Terminal resistance Ra0.59 Oh0.83 Oh+41%
Torque constant kT0.071 Nm/A0.057 Nm/A−20%
Locked-rotor current ILR = VT/Ra40.7 EIN28.9 EIN−29%
Locked-rotor torque TLR = IchLR·kT2.89 Nm1.65 Nm−43%

The takeaway: heat does double damage — it raises winding resistance (less current) und weakens the magnets (less torque per amp). A motor that is fine cold can lose close to half its stall torque once hot. Gemäß IEC 60034-1, winding temperature limits are Class B 130 ° C, Klasse F 155 ° C, and Class H 180 °C — exceeding them accelerates permanent demagnetization.

Demagnetization & Armature Reaction (peer-reviewed data)

  • Überstrom / Ankerreaktion: In einem 70 W, 24 V PM BLDC, armature reaction alone reduced peak torque by 2.8% and dropped air-gap flux density by 5.59 mT per amp from no-load to full-load (Upadhyay & Rajagopal, IEEE PEDES 2006). At stall currents (many times rated), the effect is far larger and can become permanent.
  • Thermal demagnetization: NdFeB and SmCo magnets have a negative coercive thermal coefficient, so demagnetization risk is highest at maximum operating temperature (ScienceDirect, J. Magn. Magn. Mater., 2020). Once the working point falls below the knee of the B–H curve, magnet flux — and kT — does not recover.

This is why a motor that has beenshortedor stalled repeatedly loses torque permanently; see our explainer on what happens when you short a DC motor.

Where DC Motor Torque Loss Matters Most

The dominant failure mode tracks the duty cycle and environment. Knowing your application’s main risk shortens diagnosis.

AnwendungDominant torque-loss riskWhat to watch
Automobil (Fenster, Sitze, Scheibenwischer)Stall / jam → over-current demagLocked-rotor current vs peak rating
Robotik & AGVsFrequent start-stop, gearbox frictionGear lubrication, duty-cycle heating
Medizinisch & LaborinstrumenteCommutation quality, wenig LärmStable kT, clean commutation
Elektrowerkzeuge & DrohnenHigh current, thermal demagMagnet grade, entlüften, current limit
Förderer & AutomatisierungSustained overload, HitzeAudit laden, Isolationsklasse

Robotic joints in particular depend on a reducer to multiply motor torque; a weak motor there cascades into the whole arm — our piece on why robotic arms need speed reducers explains the torque–speed trade.

Auswahlhilfe: How to Spec a DC Motor That Won’t Lose Torque

If diagnosis points to replacement, size the new motor so torque loss never becomes a field complaint.

  1. Passen Sie Spannung und Typ an: confirm PMDC, Serie, Shunt, oder BLDC, and the supply polarity/range.
  2. Size torque with margin: select rated torque at least 1.3–1.5× the worst-case load, not the average. Stall/locked-rotor torque must clear the starting load.
  3. Budget for thermal rise: pick an insulation/magnet class that keeps the winding below IEC 60034-1 limits at your duty cycle; add venting or a larger frame if the motor runs hot.
  4. Set the drive current limit correctly: für BLDC, set the limit to ~1.2–1.5× rated current for short overload headroom — too low and torque collapses under load.
  5. Choose magnet grade for temperature: NdFeB for high flux density; verify the knee point stays above your max operating temperature to avoid demag.
  6. Passen Sie den Montageflansch an: IEC B5/B14 or NEMA C-face so it drops into the existing mount — see our Motorflanschführung.

Common Engineering Mistakes That Cause Torque Loss

FehlerWhy it costs torque
Exceeding peak / pulse current ratingPermanent magnet demagnetization — kT never recovers
Undersized supply or long, thin wiresVoltage drop at the terminals → Ia ↓ → T ↓ (T roughly proportional to V)
Ignoring duty-cycle heatingMotor only weak when hot; passes a cold bench test
Wrong Hall angle (60° vs 120°) on BLDCIncorrect commutation timing → weak starting torque
Über- or under-lubricating a gearmotorGrease drag raises load torque and wastes shaft output
Reading inrush current as a faultStall current VT/Ra is normal at start; masking the real issue
Sizing by rated torque onlyNo margin for starting/overload → chronicweakfeel

DC Motor Torque-Loss Troubleshooting Table (Problem → Ursache → Lösung)

ProblemWahrscheinliche UrsacheLösung
Weak or no torque at startLow supply V, demagnetized magnets, offene Wicklung, Lager festgefressenMeasure VT at terminals; check magnet kT; test winding R; free the shaft
Torque drops only as it warms upThermal drift: Ra , kTAllow cooling; reduce duty; upgrade insulation/magnet class
Weak only under load, fine unloadedDrive current limit too low, oder echte ÜberlastungRaise current limit to 1.2–1.5× rated; Belastung reduzieren
High no-load speed but low torquePermanent demagnetizationConfirm via back-EMF / kT test vs nameplate; replace magnets or motor
Intermittent weak torqueLoose connection, thermal trip, dirty commutatorKlemmen festziehen; check current limit; clean/resurface commutator
Torque decays over monthsGradual demag, bearing wear, brush lossReplace brushes/bearings; re-lubricate; re-magnetize or replace
New motor is weak out of the boxWrong part number, wrong Hall angle, bad drive settingVerify spec; set 60°/120°; match drive parameters

For the full diagnostic sequence (including insulation and back-EMF tests), use our DC motor troubleshooting guide.

Häufig gestellte Fragen

Does low voltage reduce DC motor torque?

Ja. Torque follows T ≈ kT·(vT − Eb)/Ra, so a lower terminal voltage means less armature current and therefore less torque. A motor on a weak supply or long, thin wiring will feel sluggish and slow, especially under load, because the voltage at the terminals drops under current draw.

Can a DC motor lose torque permanently?

Yes — if the permanent magnets are demagnetized by sustained over-current or excessive heat, the torque constant kT drops and does not recover. The only fixes are re-magnetizing the magnets (rarely practical) or replacing the rotor/motor. This is why peak and stall currents must stay within the nameplate rating.

How much torque does heat cost a DC motor?

Substantial. In a documented 24 V PMDC, raising the winding temperature from 25 °C to 125 °C cut the torque constant about 20% and locked-rotor torque from ~2.9 Nm to ~1.65 Nm — roughly a 43% loss of stall torque. Heat raises winding resistance and weakens the magnets at the same time.

Why does my BLDC lose torque after a stall?

Stall current equals VT/Ra and can be many times the rated value. Sustained stall overheats the windings and demagnetizes the magnets, and most BLDC drives also impose a current limit that caps torque. Repeated stalling is the fastest route to permanent torque loss.

How do I test a DC motor for demagnetization?

Compare its actual performance to the nameplate: a demagnetized motor shows high no-load speed mit niedriges Drehmoment, and a reduced back-EMF constant (spin it as a generator and measure V per 1000 U/min) and reduced torque constant kT. A megger test (IEEE 43) checks the winding; demag is confirmed by the torque/back-EMF drop, not by insulation.

Is torque loss different in brushed vs brushless DC motors?

The magnet physics (T = kT·ICHa) is identical, but brushed motors also lose torque through brush friction and commutator wear, while brushless motors lose it through drive current limits and Hall-sensor/timing errors. A brushed motor’s torque loss is usually mechanical and repairable; a BLDC’s is often in the controller settings.

Warum Greensky für DC wählen? & Motion-Ersatzmotoren?

When torque loss points to replacement rather than repair, Greensky supplies a complete DC portfolio — PMDC, gebürstet, und bürstenlos (BLDC) Motoren plus integrierte Getriebemotoren — nach IEC gebaut 60034 und NEMA MG 1 Abmessungen, sodass sie in vorhandene Halterungen passen. For maintenance and procurement teams we provide:

  • Documented torque constants: nameplate kT, Stalldrehmoment, rated current and insulation class so your baseline is clear from day one.
  • Thermal headroom: Class F and H insulation options and magnet grades selected for your duty-cycle temperature, not just the catalog average.
  • Flanschkompatibilität: IEC B5/B14 and NEMA C-face with customized pilot diameters — see our Motorflanschführung.
  • Gebürstet oder BLDC: Wählen Sie mechanische Einfachheit oder elektronische Kommutierung mit passenden Hall-Sensoren und Antrieben.
  • Low-MOQ OEM/ODM: Kleinserien für Ersatzteilprogramme und kundenspezifische Wellen-/Encoderkonfigurationen.

Holen Sie sich ein kostenloses Angebot

Verwandte Lektüre

Referenzen

  1. IEC 60034-1 — Rotierende elektrische Maschinen: Bewertung und Leistung (temperature classes, torque definitions). webstore.iec.ch/publication/67467
  2. IEC 60034-30-1 — Effizienzklassen für rotierende elektrische Maschinen (IE1–IE5). webstore.iec.ch/publication/67784
  3. KEIN MG 1 — Motoren und Generatoren (Sicherheit, Thermal-, mounting dimensions). nema.org/standards/view/mg-1-motors-and-generators
  4. IEEE 43-2013 – Empfohlene Praxis für die Isolationswiderstandsprüfung rotierender Maschinen. Standards.ieee.org/ieee/43/4385
  5. IEEE 112 — Standard Test Procedure for Polyphase Induction & Gleichstrommotoren (Verlust & Back-EMF-Methoden). Standards.ieee.org/ieee/112/4213
  6. UNS. DOE – Bestimmung des Wirkungsgrads von Elektromotoren & Repair Guidance. energy.gov/eere/amo/articles/determination-electric-motors
  7. SKF – Lagerwartung und -schmierung für Elektromotoren. skf.com/us/products/maintenance-products/ Bearing-maintenance
  8. Haydon Kerk Pittman — Temperature Effects on DC Motor Performance (thermal torque-constant model). haydonkerkpittman.com/learningzone/whitepapers/temperature-effects-on-dc-motor-performance
  9. FAULHABER — DC-Motors Technical Information (kM, kE, α coefficients, Stalldrehmoment). faulhaber.com/de/technische-informationen
  10. maxon — DC motor commutation and application notes. maxon.com/en-us/technologies/tech-papers

Sie können auch mögen

Motoren für Krankenhauslieferroboter: BLDC & Leitfaden zur Auswahl von Servoantrieben | GreenSky

Motoren für Lager-FTFs: Typen, Spezifikationen & Auswahl nach Fahrzeugklasse | GreenSky

Verlassen Sie das Raster

Senden Sie noch heute Ihre Anfrage

Bild von Kyle

Kyle

Vertriebsingenieur | Erfahrener Komplettlieferant von Elektromotoren in China (Gleichstrommotor/BLDC-Motor/Schrittmotor/Getriebemotor)
Greensky betreibt WeChat

Bitte hinterlassen Sie Ihre geschäftliche E-Mail-Adresse.

Teilen Sie uns Ihre Bedürfnisse mit